Skip to main content Skip to search
Displaying 1 - 4 of 4
A novel hyphenated method based on ultrasound-assisted dispersive liquid-liquid microextraction coupled to precolumn derivatization has been established for the simultaneous determination of bisphenol A, 4-octylphenol, and 4-nonylphenol by high-performance liquid chromatography with fluorescence detection. Different parameters that influence microextraction and derivatization have been optimized. The quantitative linear range of analytes is 5.0-400.0 ng/L, and the correlation coefficients are more than 0.9998. Limits of detection for soft drinks and dairy products have been obtained in the range of 0.5-1.2 ng/kg and 0.01-0.04 μg/kg, respectively. Relative standard deviations of intra- and inter-day precision for retention time and peak area are in the range of 0.47-2.31 and 2.76-8.79%, respectively. Accuracy is satisfactory in the range of 81.5-118.7%. Relative standard deviations of repeatability are in the range of 0.35-1.43 and 2.36-4.75% for retention time and peak area, respectively. Enrichment factors for bisphenol A, 4-octylphenol, and 4-nonylphenol are 170.5, 240.3, and 283.2, respectively. The results of recovery and matrix effect are in the range of 82.7-114.9 and 92.0-109.0%, respectively. The proposed method has been applied to the determination of bisphenol A, 4-octylphenol, and 4-nonylphenol in soft drinks and dairy products with much higher sensitivity than many other methods.

A novel hyphenated technique based on ultrasonic-assisted dispersive liquid-liquid microextraction (UA-DLLME) coupled with derivatization has been established for the determination of brassinolide (BL, a representative of brassinosteroids) by HPLC fluorescence detection. 9-Phenanthreneboronic acid is used as labeling reagent of BL. UA-DLLME parameters containing type and volume of extraction and disperser solvent, pH and ultrasonication time are optimized. Derivatization parameters are optimized included amount of 9-phenanthreneboronic acid, volume ratio of pyridine, derivatization time and temperature. Under optimal conditions, quantitative linear range of BL is 50-1,000 ng L<sup>−1</sup> and excellent linear response is observed with correlation coefficient of 0.9996. Limit of detection and limit of quantification are calculated as 8.0 and 25.0 ng L<sup>−1</sup>, respectively. RSDs of retention time and peak area are in the range of 0.68-0.97 % and 4.61-6.54 % for intra-day precision, 1.32-1.94 % and 7.28-9.75 % for inter-day precision, respectively. Accuracy is satisfactory in the range of 82.3-125.1 %. RSDs’ values of repeatability are in the range of 0.82-1.79 and 3.95-8.53 % for retention time and peak area, respectively. Enrichment factor for BL is 189. The results of recovery and matrix effect are in the range of 82.0-108.6 and 90.0-115.3 %, respectively. The proposed method has been applied for the determination of BL in <i>Arabidopsis thaliana</i>, <i>Daucus carota</i> and <i>Brassica campestris</i> L. leaves with much higher sensitivity than many other methods.

• A new low toxic dual-UADLLME coupled with microwave-assisted derivatization was proposed. • 4′-Carboxy-substituted rosamine was firstly used as derivatization reagent. • Simultaneous determination of PPD and PPT in rat plasma was achieved by UHPLC-MS/MS. • This method was successfully applied to pharmacokinetics study.<br>This paper, for the first time, reported a speedy hyphenated technique of low toxic dual ultrasonic-assisted dispersive liquid-liquid microextraction (dual-UADLLME) coupled with microwave-assisted derivatization (MAD) for the simultaneous determination of 20(<b>S</b>)-protopanaxadiol (PPD) and 20(<b>S</b>)-protopanaxatriol (PPT). The developed method was based on ultra high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) detection using multiple-reaction monitoring (MRM) mode. A mass spectrometry sensitizing reagent, 4′-carboxy-substituted rosamine (CSR) with high reaction activity and ionization efficiency was synthesized and firstly used as derivatization reagent. Parameters of dual-UADLLME, MAD and UHPLC-MS/MS conditions were all optimized in detail. Low toxic brominated solvents were used as extractant instead of traditional chlorinated solvents. Satisfactory linearity, recovery, repeatability, accuracy and precision, absence of matrix effect and extremely low limits of detection (LODs, 0.010 and 0.015 ng/mL for PPD and PPT, respectively) were achieved. The main advantages were rapid, sensitive and environmentally friendly, and exhibited high selectivity, accuracy and good matrix effect results. The proposed method was successfully applied to pharmacokinetics of PPD and PPT in rat plasma.